Water meters WP-R160
R160 Woltman Water Meter
A flanged Woltmann meter for bulk lines, DN50 to DN200.
- Nominal size
- DN50 DN65 DN80 DN100 DN125 DN150 DN200
- Q3 permanent flow
- 40 m³/h 63 m³/h 100 m³/h 160 m³/h 250 m³/h 400 m³/h 630 m³/h
- R value (Q3/Q1)
- 160 160 160 160 160 160 160
- Accuracy class
- 2 2 2 2 2 2 2
Select nominal size (DN)
Specifications update with the selected size.
Overview
Why buyers choose it
-
R160 turndown
Accuracy holds from Q3/160 upward, so the low night flow on a district line still registers instead of passing unmeasured.
-
Sealed to IP68
The register is hermetically sealed, which is what keeps a meter readable after a chamber has flooded.
-
Removable measuring element
The element is pattern approved and lifts out, so re-verification does not mean taking the body out of the line.
-
Reads from any angle
The register turns through a full 360°, so the meter is set to suit the pipe and still faces the access hatch.
In detail
A Woltmann meter measures with a helical rotor set along the axis of the pipe rather than across it, which is what lets it take the volumes a bulk line carries. The R160 covers DN50 to DN200, with permanent flow rates from 40 to 630 m³/h, and connects by flange.
The R160 in the name is the turndown. The meter holds class 2 accuracy from a minimum flow of Q3/160 upward — ±5% between Q1 and Q2, tightening to ±2% from Q2 to overload. That range is the whole argument for the meter on a district line, where night flow is a small fraction of the daytime peak and a meter that stops registering at the bottom of its range is where unaccounted-for water begins.
The register is hermetically sealed to IP68 and turns through a full 360°, so the meter can be installed to suit the pipe and still be read from the access side of the chamber. The measuring element is pattern approved and removable, so re-verification does not mean cutting the body out of the line. The body is powder coated against corrosion, and the register is unaffected by external magnetic fields.
Installation is orientation-sensitive and the meter expects a settled flow profile: ten diameters of straight pipe upstream and five downstream. A remote transmission device can be fitted on request, with pulse output at 100 or 1000 litres per pulse.
Technical specifications
Selected size: DN50 DN65 DN80 DN100 DN125 DN150 DN200
Values shown apply to the selected size. A dash means the figure is not stated.
Metrological
| Nominal size | DN50 DN65 DN80 DN100 DN125 DN150 DN200 |
|---|---|
| R value (Q3/Q1) | 160 |
| Accuracy class | 2 |
| Register type | Dry dial, hermetically sealed to IP68 |
| Maximum permissible error, Q1 to Q2 | ±5% |
| Maximum permissible error, Q2 to Q4 | ±2% for water having a temperature ≤30℃; ±3% for water having a temperature >30℃ |
| Indicating range | 999,999 |
| Resolution of indicating device | 0.0005 |
Hydraulic
| Q3 permanent flow | 40 m³/h 63 m³/h 100 m³/h 160 m³/h 250 m³/h 400 m³/h 630 m³/h |
|---|---|
| Q1 minimum flow | — 0.394 m³/h 0.625 m³/h 1 m³/h 1.5625 m³/h 2.5 m³/h 3.9375 m³/h |
| Maximum working pressure | 16 bar |
| Pressure loss class | ΔP40 |
| Q2 transitional flow | — 0.63 m³/h 1 m³/h 1.6 m³/h 2.5 m³/h 4 m³/h 6.3 m³/h |
| Q4 overload flow | — 78.75 m³/h 125 m³/h 200 m³/h 312.5 m³/h 500 m³/h 787.5 m³/h |
| Flow profile sensitivity class | U10 D5 |
Environmental
| Temperature class | T30 / T50 |
|---|
Approvals
| Standards | ISO 4064 |
|---|
Dimensions and installation
| Connection thread | Flange |
|---|---|
| Length | 200 mm 200 mm 225 mm 250 mm 250 mm 300 mm 350 mm |
| Weight | 8 kg 9.5 kg 14.5 kg 16.8 kg 20 kg 36 kg 44.5 kg |
| Orientation limitation | Yes |
| Height | 200 mm 208 mm 245 mm 245 mm 275 mm 350 mm 370 mm |
| Width | 165 mm 185 mm 200 mm 200 mm 220 mm 285 mm 347 mm |
| Flange outside diameter | 160 mm 180 mm 195 mm 215 mm 245 mm 285 mm 340 mm |
| Bolt circle diameter | 125 mm 145 mm 160 mm 180 mm 210 mm 240 mm 295 mm |
| Connecting bolts | 4 × M16 4 × M16 8 × M16 8 × M16 8 × M16 8 × M20 12 × M20 |
Parts
Parts of a Woltmann meter
How a meter of this type is built, and what this model is made of.
-
Register cover
Caps the register and keeps water and debris off the dial.
-
Register
Totalises and displays the water passed.
Register type Dry dial, hermetically sealed to IP68
-
Register seal
Seals the register housing against water ingress.
-
Chamber cover
Bolted cover giving access to the measuring element inside the body.
-
Helical-vane rotor
Spins with the flow along its helical vanes and drives the register through a gear train.
-
Body
Flanged cast body that houses the rotor and carries the flow.
-
Flange gaskets and bolts
Seal and secure the flanged joints to the pipeline.
Download centre
Everything you need to specify.
Documents for the R160 Woltman Water Meter.
-
Download PDF (Opens in a new tab) Download PDF (Opens in a new tab) Download PDF (Opens in a new tab) Download PDF (Opens in a new tab) Download PDF (Opens in a new tab) Download PDF (Opens in a new tab) Download PDF (Opens in a new tab)
Technical datasheet
Specifications and dimensions for DN50.
Specifications and dimensions for DN65.
Specifications and dimensions for DN80.
Specifications and dimensions for DN100.
Specifications and dimensions for DN125.
Specifications and dimensions for DN150.
Specifications and dimensions for DN200.
-
Download PDF (Opens in a new tab)
All sizes datasheet
Every size in one sheet.