Flow meters US-2500

Ultrasonic Flow Meter

Transit-time ultrasonic, clamp-on or inline, DN15 to DN6000.

Measuring principle
Ultrasonic, transit time
Pipe size range
DN15 to DN6000
Accuracy
±1%
Outputs
4–20 mA and pulse

Overview

Why buyers choose it

  • Measures without cutting

    Clamp-on transducers on a live pipe: no shutdown, no welding, no pressure test afterwards.

  • Three ways to fit it

    Clamp-on for a survey, insertion above 80 mm, or an inline spool to DN600 — same electronics.

  • Conductivity does not matter

    Oils, alcohols, acids and solvents all measurable, where an electromagnetic meter reads nothing.

  • Logs on board

    Up to 8 GB on an SD card, so a survey does not need a network at the pipe.

In detail

The clamp-on form is the reason this meter gets specified. Two transducers strap to the outside of an existing pipe and the flow is read by timing an ultrasonic pulse with and against it. No cutting, no welding, no shutdown, no pressure test afterwards — which on a live main is the difference between a measurement this week and a measurement next quarter.

It reads through steel, cast iron, ductile iron, brass, copper, PVC and aluminium, and the transducer set is chosen by bore: S1 covers 15 to 100 mm, M1 covers 50 to 700 mm, and L1 reaches 4,570 mm. Where a permanent installation is wanted instead, the same electronics take an insertion probe above 80 mm or an inline spool from DN15 to DN600.

What you give up against an electromagnetic meter is a little accuracy — ±1% rather than ±0.5% — and the requirement for a reasonably clean liquid. What you gain is that it does not care whether the liquid conducts, so oils, alcohols, acids and solvents are all measurable, and there is nothing wetted to corrode.

An SD card option logs on board, up to 8 GB, so a survey meter can be left on a pipe for a fortnight and read when it comes back rather than needing a network at the pipe.

Technical specifications

Metrological

Measuring principle Ultrasonic, transit time
Accuracy ±1%
Repeatability ±0.2% of span
Velocity range 0.3 to 32 m/s

Hydraulic

Measured media Domestic, industrial, raw and ground water; sewage with small particle content; oils; chemicals; alcohol; acids
Medium temperature Below 60 °C at the meter; liquid −40 to 121 °C, optionally 40 to 250 °C
Maximum working pressure Inline type: 5 or 10 kg/cm², or below 40 kg/cm²

Materials

Body material Inline type: carbon or mild steel, SS304, SS316, plastic or brass
Enclosure material Plastic or aluminium

Electrical

Power supply 230 V AC, 110 V AC, 24 V DC or battery
Outputs 4–20 mA and pulse
Display Four lines of sixteen characters

Communication

Communication RS-232C, RS485, M-Bus, RF, GSM/GPRS or LoRa/NB-IoT

Environmental

Protection class IP65, IP67 or IP68
Explosion protection Flameproof (FLP)
Ambient conditions −20 to +60 °C, 5% to 90% humidity

Dimensions and installation

Schematic, not to scale
Pipe size range DN15 to DN6000
End connection Clamp-on, insertion above 80 mm, or inline DN15 to DN600
Transmitter mounting Integral or remote