Flow meters EMI-2000

Insertion Electromagnetic Flow Meter

An electromagnetic probe for large pipes, DN150 to DN2000, fitted through a single branch.

Pipe size range
DN150 to DN2000
Velocity range
0.1 to 10 m/s
Accuracy
±2% of full scale
Outputs
4–20 mA

Overview

Why buyers choose it

  • One probe, DN150 to DN2000

    Fitted through a 2 in flanged branch, so a large main needs a tapping rather than a cut-in spool.

  • No pressure loss

    Nothing crosses the flow, and there is no rotor or bearing to wear.

  • Down to 20 µS/cm

    Water and other conductive liquids, corrosive or not; density and viscosity do not shift the reading.

  • ±2% of full scale

    A single-point velocity reading scaled by a profile factor that depends on the bore.

In detail

An insertion meter measures velocity at one point in the pipe instead of across the whole bore. A stainless steel probe carries the coils and two SS316L electrodes. It enters the pipe through a 2 in ASA 150# flanged branch fitted with a ball valve, and the transmitter turns the local velocity into flow for the bore it has been set up for.

That is its case on large pipes. A full-bore meter at DN1000 means a spool the size of the main and a length of pipe cut out to fit it; this probe covers DN150 to DN2000 with one body and a tapping. It puts nothing across the flow, so there is no pressure loss, and it has no rotor or bearing to wear or to stop in dirty water.

The cost is accuracy. A single-point reading is scaled by a velocity profile factor that depends on the bore, from about 0.85 at DN200 to about 0.87 at DN2000, and the meter is rated at ±2% of full scale. Velocity range is 0.1 to 10 m/s.

The liquid must conduct at 20 µS/cm or more; above that, changes in density, viscosity, pressure, temperature and conductivity do not move the reading, and corrosive liquids are measured as readily as water. Media temperature is 0 to 80 °C and operating pressure up to 10 kg/cm², with 15 kg/cm² as the maximum media pressure. The coils are driven with pulsed DC at 3 Hz to hold the zero steady, and an empty pipe reads as zero flow.

The transmitter is integral as standard, or remote on request, in a die-cast aluminium housing to IP68 with an IP67 terminal box. A 16×2 LCD shows a four-digit flow rate and an eight-digit total in m³/h, LPH, LPM or other units, and damping is adjustable from 5 to 30 s. Outputs are 4–20 mA and RS485, with a reverse-flow output as an option, and it runs on 90–250 V AC at 50 Hz or 24 V DC.

Technical specifications

Metrological

Measuring principle Electromagnetic insertion probe, pulsed DC coil excitation at 3 Hz
Accuracy ±2% of full scale
Velocity range 0.1 to 10 m/s

Hydraulic

Measured media Conductive liquids from 20 µS/cm, corrosive or non-corrosive, including water
Medium temperature 0 to 80 °C
Maximum working pressure 10 kg/cm² operating; 15 kg/cm² maximum media pressure

Materials

Body material Probe SS304; construction stainless steel or mild steel
Electrode material SS316L
Enclosure material Die-cast aluminium

Electrical

Power supply 90–250 V AC, 50 Hz, or 24 V DC
Outputs 4–20 mA
Display 16×2 LCD, 4-digit flow rate and 8-digit total, with unit conversion

Communication

Communication RS485

Environmental

Protection class Transmitter IP68, terminal box IP67
Ambient conditions 0 to 50 °C, up to 90% RH, non-condensing

Dimensions and installation

Schematic, not to scale
Pipe size range DN150 to DN2000
End connection 2 in ASA 150# flanged branch
Transmitter mounting Integral as standard, remote on request

Parts

Parts of an electromagnetic meter

How a meter of this type is built, and what this model is made of.

Parts of an electromagnetic meter, drawn illustration Exploded illustration of an electromagnetic flow meter's parts, numbered top to bottom: 1 transmitter with display, 2 cable entry, 3 field coil, 4 electrodes, 5 insulating liner, 6 measuring tube, 7 earthing rings, 8 flanges. 1 2 3 4 5 6 7 8
Illustrative: how a meter of this type is built. This model's own materials and figures are in the table and its specifications.
  1. Transmitter with display

    Converts the electrode signal into a flow reading and shows it.

    Display 16×2 LCD, 4-digit flow rate and 8-digit total, with unit conversion

  2. Cable entry

    Where the signal and power cables enter the transmitter housing.

  3. Field coil

    Generates the magnetic field the flow induces a voltage across.

  4. Electrodes

    Sense the voltage induced by the flowing liquid.

    Electrode material SS316L

  5. Insulating liner

    Isolates the measuring signal from the metal tube wall.

  6. Measuring tube

    Carries the flow through the magnetic field.

    Body material Probe SS304; construction stainless steel or mild steel

  7. Earthing rings

    Reference the liquid to the pipework's earth potential.

  8. Flanges

    Bolt the meter to the pipeline.

    End connection 2 in ASA 150# flanged branch

Download centre

Everything you need to specify.

Documents for the Insertion Electromagnetic Flow Meter.

Approvals and certificates

Ready to get started?

Tell us about your scheme, society or plant.

Our team will help you find the right solution for your water needs.

Chat on WhatsApp

Compare